Surgeon Estimations of Acetabular Cup Orientation Using Intraoperative Fluoroscopic Imagining Are Unreliable.

Document Type

Article

Publication Date

4-2023

Abstract

BACKGROUND: Accurate acetabular cup orientation is associated with decreased revision rates and improved outcomes of primary total hip arthroplasty. This study assesses surgeon's ability to estimate both the acetabular component inclination and anteversion angles via intraoperative fluoroscopy (IF) images.

METHODS: We surveyed orthopedic surgeons to estimate acetabular component inclination and anteversion based on 20 IF images of total hip arthroplasty through a direct anterior approach. Postoperative computed-tomography scans were used to calculate the true inclination and anteversion component angles. The absolute difference between the true and estimated values was calculated to determine the mean and standard deviation of the survey results. Interrater reliability was determined through interclass correlation coefficients.

RESULTS: A majority of surgeons preferred the direct anterior approach (83.3%) and utilized IF during surgery (70%). Surgeons surveyed were on average 5.9° away from the true value of inclination (standard deviation = 4.7) and 8.8° away from the true value of anteversion (standard deviation = 6.0). Respondents were within 5° of both inclination and anteversion in 19.7% of cases, and within 10° in 57.3% of cases. All surgeons were determined to have poor reliability in estimating anteversion (interclass correlation coefficient < 0.5). Only 2 surgeons were determined to have moderate reliability when estimating inclination.

CONCLUSIONS: Surgeons, when solely relying on IF for the estimation of anteversion and inclination, are unreliable. Utilization of other techniques in conjunction with IF would improve observer reliability.

Publication Title

Arthroplast Today

Volume

20

First Page

101109

Last Page

101109

Share

COinS